{"id":13507,"date":"2026-08-07T13:13:45","date_gmt":"2026-08-07T10:13:45","guid":{"rendered":"https:\/\/localhost\/wordpress\/?post_type=product&#038;p=13507"},"modified":"2026-09-09T10:01:01","modified_gmt":"2026-09-09T07:01:01","slug":"proctor-moulds-and-rammers","status":"publish","type":"product","link":"https:\/\/www.liyatest.com.tr\/en\/urun\/proctor-moulds-and-rammers\/","title":{"rendered":"Proctor Moulds and Rammers"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text css=&#8221;&#8221; woodmart_inline=&#8221;no&#8221; text_larger=&#8221;no&#8221;]<\/p>\n<h2 class=\"PDq2pG_selectionAnchorContainer\" data-start=\"4597\" data-end=\"4636\">What Are Proctor Moulds and Rammers?<\/h2>\n<p data-start=\"4638\" data-end=\"4823\"><strong data-start=\"4638\" data-end=\"4668\">Proctor Moulds and Rammers<\/strong> are laboratory accessories used to determine the relationship between the water content and dry density of soils and selected road construction materials.<\/p>\n<p data-start=\"4825\" data-end=\"5010\">During a Proctor compaction test, the prepared material is placed into a mould in several layers. Each layer is compacted using a specified rammer mass, drop height and number of blows.<\/p>\n<p data-start=\"5012\" data-end=\"5225\">The procedure is repeated at different moisture contents. The resulting measurements are used to establish a compaction curve and determine the <strong data-start=\"5156\" data-end=\"5208\">optimum moisture content and maximum dry density<\/strong> of the material.<\/p>\n<p data-start=\"5227\" data-end=\"5471\">Different international test methods require different mould dimensions, rammer masses and free-fall heights. Liya Test therefore provides ASTM, EN and BS-type configurations within the same product family.<\/p>\n<h2 data-start=\"5473\" data-end=\"5514\">ASTM Standard Proctor Mould and Rammer<\/h2>\n<p data-start=\"5516\" data-end=\"5643\">The <strong data-start=\"5520\" data-end=\"5555\">LT-S0055 Standard Proctor Mould<\/strong> has an internal diameter of <strong data-start=\"5584\" data-end=\"5602\">101.6 \u00b1 0.4 mm<\/strong> and a body height of <strong data-start=\"5624\" data-end=\"5642\">116.4 \u00b1 0.5 mm<\/strong>.<\/p>\n<p data-start=\"5645\" data-end=\"5808\">The corresponding <strong data-start=\"5663\" data-end=\"5699\">LT-S0057 Standard Proctor Rammer<\/strong> has a nominal diameter of <strong data-start=\"5726\" data-end=\"5737\">50.8 mm<\/strong>, a mass of <strong data-start=\"5749\" data-end=\"5764\">2495 \u00b1 23 g<\/strong> and a free-fall height of <strong data-start=\"5791\" data-end=\"5807\">304.8 \u00b1 1 mm<\/strong>.<\/p>\n<p data-start=\"5810\" data-end=\"6138\">These dimensions are consistent with the standard-effort laboratory compaction arrangement used in <strong data-start=\"5909\" data-end=\"5931\">ASTM D698-12(2021)<\/strong>. ASTM describes a 101.6 or 152.4 mm mould with an approximately 2.5 kg rammer dropped from about 305 mm to produce a compactive effort of approximately <strong data-start=\"6084\" data-end=\"6099\">600 kN\u00b7m\/m\u00b3<\/strong>.<\/p>\n<h2 data-start=\"6140\" data-end=\"6174\">ASTM Modified Proctor Equipment<\/h2>\n<p data-start=\"6176\" data-end=\"6248\">Higher compaction energy is required for the modified Proctor procedure.<\/p>\n<p data-start=\"6250\" data-end=\"6377\">The <strong data-start=\"6254\" data-end=\"6289\">LT-S0056 Modified Proctor Mould<\/strong> has an internal diameter of <strong data-start=\"6318\" data-end=\"6336\">152.4 \u00b1 0.7 mm<\/strong> and a body height of <strong data-start=\"6358\" data-end=\"6376\">116.4 \u00b1 0.5 mm<\/strong>.<\/p>\n<p data-start=\"6379\" data-end=\"6520\">The <strong data-start=\"6383\" data-end=\"6419\">LT-S0058 Modified Proctor Rammer<\/strong> has a diameter of <strong data-start=\"6438\" data-end=\"6449\">50.8 mm<\/strong>, a mass of <strong data-start=\"6461\" data-end=\"6476\">4540 \u00b1 10 g<\/strong> and a free-fall height of <strong data-start=\"6503\" data-end=\"6519\">457 \u00b1 1.3 mm<\/strong>.<\/p>\n<p data-start=\"6522\" data-end=\"6764\">The current <strong data-start=\"6534\" data-end=\"6557\">ASTM D1557-12(2021)<\/strong> defines modified-effort laboratory compaction using an approximately 4.5 kg rammer dropped from 457 mm, producing a compactive effort of approximately <strong data-start=\"6709\" data-end=\"6725\">2700 kN\u00b7m\/m\u00b3<\/strong>.<\/p>\n<h2 data-start=\"6766\" data-end=\"6807\">EN Type A and Type B Proctor Equipment<\/h2>\n<p data-start=\"6809\" data-end=\"6889\">For EN applications, Liya Test provides <strong data-start=\"6849\" data-end=\"6888\">Type A and Type B Proctor equipment<\/strong>.<\/p>\n<p data-start=\"6891\" data-end=\"7024\">The <strong data-start=\"6895\" data-end=\"6937\">LT-S0060 Type A Standard Proctor Mould<\/strong> has a nominal internal diameter of <strong data-start=\"6973\" data-end=\"6987\">100 \u00b1 1 mm<\/strong> and a body height of <strong data-start=\"7009\" data-end=\"7023\">120 \u00b1 1 mm<\/strong>.<\/p>\n<p data-start=\"7026\" data-end=\"7190\">The corresponding <strong data-start=\"7044\" data-end=\"7087\">LT-S0062 Type A Standard Proctor Rammer<\/strong> has a diameter of <strong data-start=\"7106\" data-end=\"7121\">50 \u00b1 0.5 mm<\/strong>, a mass of <strong data-start=\"7133\" data-end=\"7148\">2500 \u00b1 20 g<\/strong> and a free-fall height of <strong data-start=\"7175\" data-end=\"7189\">305 \u00b1 3 mm<\/strong>.<\/p>\n<p data-start=\"7192\" data-end=\"7306\">The <strong data-start=\"7196\" data-end=\"7239\">LT-S0063 Type B Modified Proctor Rammer<\/strong> uses a <strong data-start=\"7247\" data-end=\"7262\">4500 \u00b1 40 g<\/strong> mass and a <strong data-start=\"7274\" data-end=\"7288\">457 \u00b1 3 mm<\/strong> free-fall height.<\/p>\n<p data-start=\"7308\" data-end=\"7638\"><strong data-start=\"7308\" data-end=\"7330\">BS EN 13286-2:2010<\/strong> specifies Proctor compaction methods for determining the relationship between water content and dry density of unbound and hydraulically bound mixtures used in road construction and civil engineering works. BSI currently lists the standard as <strong data-start=\"7574\" data-end=\"7599\">Current, Under Review<\/strong>.<\/p>\n<h2 data-start=\"7640\" data-end=\"7678\">Galvanized Steel Mould Construction<\/h2>\n<p data-start=\"7680\" data-end=\"7796\">The Proctor moulds are manufactured from plated or galvanized steel and are supplied as a laboratory mould assembly.<\/p>\n<p data-start=\"7798\" data-end=\"8033\">The typical configuration includes the <strong data-start=\"7837\" data-end=\"7884\">mould body, extension collar and base plate<\/strong>. The removable collar allows the material to be compacted slightly above the mould body before the excess material is trimmed to the required level.<\/p>\n<p data-start=\"8035\" data-end=\"8140\">Durable steel construction supports repeated impact loading during routine laboratory compaction testing.<\/p>\n<h2 data-start=\"8142\" data-end=\"8180\">Soil-Cement Compaction Applications<\/h2>\n<p data-start=\"8182\" data-end=\"8230\">The product group also references <strong data-start=\"8216\" data-end=\"8229\">ASTM D558<\/strong>.<\/p>\n<p data-start=\"8232\" data-end=\"8526\">The active version is <strong data-start=\"8254\" data-end=\"8276\">ASTM D558\/D558M-19<\/strong>, which determines the relationship between water content and density of soil-cement mixtures before cement hydration. The method uses a 944 cm\u00b3 mould and an approximately 2.5 kg rammer dropped from about 305 mm.<\/p>\n<p data-start=\"8528\" data-end=\"8701\">This standard is therefore relevant when the mould and rammer equipment is used for soil-cement specimen preparation rather than conventional untreated-soil Proctor testing.<\/p>\n<h2 data-start=\"8703\" data-end=\"8746\">Standard and Modified Compaction Testing<\/h2>\n<p data-start=\"8748\" data-end=\"8820\">Standard and modified Proctor methods use different compactive energies.<\/p>\n<p data-start=\"8822\" data-end=\"9047\">The standard procedure applies lower impact energy, while the modified method uses a heavier rammer and greater drop height. This allows laboratories to evaluate material behaviour under different levels of compaction effort.<\/p>\n<p data-start=\"9049\" data-end=\"9207\">Correct selection of the mould, rammer mass and drop height is essential because these parameters directly affect the resulting moisture-density relationship.<\/p>\n<p data-start=\"9209\" data-end=\"9383\">Overall, <strong data-start=\"9218\" data-end=\"9248\">Proctor Moulds and Rammers<\/strong> provide the basic equipment required for controlled standard and modified compaction testing of soils and road construction materials.<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p><strong><span dir=\"auto\" style=\"vertical-align: inherit;\">STANDART:\u00a0<\/span><\/strong><span dir=\"auto\" style=\"vertical-align: inherit;\"> ASTM D 698, D 1557, D 558 ; AASHTO T 99, T180, T 134 ; TS EN 13286-2; BS 1377:4, 1924:2; TS 1900-1<\/span><\/p>\n<p><strong>LT-S0055<\/strong><em>\u00a0 \u00a0 \u00a0 \u00a0Standard Proctor Mould <\/em>|<em> ASTM<\/em><\/p>\n<p><strong>LT-S0056<\/strong><em>\u00a0 \u00a0 \u00a0 \u00a0Modified Proctor Mould <\/em>|<em> ASTM<\/em><\/p>\n<p><strong>LT-S0060<\/strong><em>\u00a0 \u00a0 \u00a0 Standard Proctor Mould \u00a0<\/em>|<em> EN, A Tipi<\/em><\/p>\n<p><strong>LT-S0061<\/strong><em>\u00a0 \u00a0 \u00a0 Modified Proctor Mould \u00a0<\/em>|<em> EN, B Tipi<\/em><\/p>\n<p><strong>LT-S0065<\/strong><em>\u00a0 \u00a0 \u00a0 Standard Proctor Mould \u00a0<\/em>|<em> EN, 1 Litre<\/em><\/p>\n<p><strong>LT-S0057<\/strong><em>\u00a0 \u00a0 \u00a0 Standard Proctor Rammer \u00a0<\/em>|<em> ASTM<\/em><\/p>\n<p><strong>LT-S0058<\/strong><em>\u00a0 \u00a0 \u00a0 Modified Proctor Rammer <\/em>|<em> ASTM<\/em><\/p>\n<p><strong>LT-S0062<\/strong><em>\u00a0 \u00a0 \u00a0 Standard Proctor Rammer \u00a0<\/em>|<em> EN, A Tipi<\/em><\/p>\n<p><strong>LT-S0063<\/strong><em>\u00a0 \u00a0 \u00a0 Modified Proctor Rammer \u00a0<\/em>|<em> EN, B Tipi<\/em><\/p>\n<p><a href=\"https:\/\/www.liyatest.com.tr\/urun\/otomatik-toprak-kompaktoru\/\"><strong>LT-S0075<\/strong><em>\u00a0 \u00a0 \u00a0 Automatic Soil Compactor<\/em><\/a><\/p>\n","protected":false},"featured_media":11800,"template":"","meta":[],"product_brand":[],"product_cat":[163,161],"product_tag":[],"class_list":["post-13507","product","type-product","status-publish","has-post-thumbnail","product_cat-compacted-road-base-subbase-soil-testing","product_cat-soil","first","instock","shipping-taxable","product-type-grouped"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Proctor Moulds and Rammers | Soil Compaction Testing | Liya Test<\/title>\n<meta name=\"description\" content=\"Proctor Moulds and Rammers for standard and modified soil compaction testing according to ASTM, EN and BS laboratory methods.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.liyatest.com.tr\/en\/urun\/proctor-moulds-and-rammers\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Proctor Moulds and Rammers | Soil Compaction Testing | Liya Test\" \/>\n<meta property=\"og:description\" content=\"Proctor Moulds and Rammers for standard and modified soil compaction testing according to ASTM, EN and BS laboratory methods.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.liyatest.com.tr\/en\/urun\/proctor-moulds-and-rammers\/\" \/>\n<meta property=\"og:site_name\" content=\"L\u0130YA TEST\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/p\/LYA-LABORATUVAR-TEST-CHAZLARI-MALAT-PAZARLAMA-100069030777066\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-09T07:01:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/localhost\/wordpress\/wp-content\/uploads\/2026\/08\/LT_PROKTORKALIPTOKMAK.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"1200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/proctor-moulds-and-rammers\\\/\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/proctor-moulds-and-rammers\\\/\",\"name\":\"Proctor Moulds and Rammers | Soil Compaction Testing | Liya Test\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/proctor-moulds-and-rammers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/proctor-moulds-and-rammers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/LT_PROKTORKALIPTOKMAK.jpg\",\"datePublished\":\"2026-08-07T10:13:45+00:00\",\"dateModified\":\"2026-09-09T07:01:01+00:00\",\"description\":\"Proctor Moulds and Rammers for standard and modified soil compaction testing according to ASTM, EN and BS laboratory methods.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/proctor-moulds-and-rammers\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/proctor-moulds-and-rammers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/proctor-moulds-and-rammers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/LT_PROKTORKALIPTOKMAK.jpg\",\"contentUrl\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/LT_PROKTORKALIPTOKMAK.jpg\",\"width\":1200,\"height\":1200,\"caption\":\"Proktor Kal\u0131p ve Tokmaklar ASTM ve EN zemin s\u0131k\u0131\u015ft\u0131rma ekipmanlar\u0131\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/proctor-moulds-and-rammers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Anasayfa\",\"item\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Proctor Moulds and Rammers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/\",\"name\":\"L\u0130YA TEST\",\"description\":\"DISCOVER THE QUALITY\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#organization\",\"name\":\"L\u0130YA LABORATUVAR TEST C\u0130HAZLARI\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/logo-footer.png\",\"contentUrl\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/logo-footer.png\",\"width\":220,\"height\":113,\"caption\":\"L\u0130YA LABORATUVAR TEST C\u0130HAZLARI\"},\"image\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/p\\\/LYA-LABORATUVAR-TEST-CHAZLARI-MALAT-PAZARLAMA-100069030777066\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/liya-testing-equipment-9b7997106\\\/\",\"https:\\\/\\\/www.instagram.com\\\/liya_test_equipment\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Proctor Moulds and Rammers | Soil Compaction Testing | Liya Test","description":"Proctor Moulds and Rammers for standard and modified soil compaction testing according to ASTM, EN and BS laboratory methods.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.liyatest.com.tr\/en\/urun\/proctor-moulds-and-rammers\/","og_locale":"en_US","og_type":"article","og_title":"Proctor Moulds and Rammers | Soil Compaction Testing | Liya Test","og_description":"Proctor Moulds and Rammers for standard and modified soil compaction testing according to ASTM, EN and BS laboratory methods.","og_url":"https:\/\/www.liyatest.com.tr\/en\/urun\/proctor-moulds-and-rammers\/","og_site_name":"L\u0130YA TEST","article_publisher":"https:\/\/www.facebook.com\/p\/LYA-LABORATUVAR-TEST-CHAZLARI-MALAT-PAZARLAMA-100069030777066\/","article_modified_time":"2026-09-09T07:01:01+00:00","og_image":[{"width":1200,"height":1200,"url":"https:\/\/localhost\/wordpress\/wp-content\/uploads\/2026\/08\/LT_PROKTORKALIPTOKMAK.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/proctor-moulds-and-rammers\/","url":"https:\/\/www.liyatest.com.tr\/en\/urun\/proctor-moulds-and-rammers\/","name":"Proctor Moulds and Rammers | Soil Compaction Testing | Liya Test","isPartOf":{"@id":"https:\/\/www.liyatest.com.tr\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/proctor-moulds-and-rammers\/#primaryimage"},"image":{"@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/proctor-moulds-and-rammers\/#primaryimage"},"thumbnailUrl":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/08\/LT_PROKTORKALIPTOKMAK.jpg","datePublished":"2026-08-07T10:13:45+00:00","dateModified":"2026-09-09T07:01:01+00:00","description":"Proctor Moulds and Rammers for standard and modified soil compaction testing according to ASTM, EN and BS laboratory methods.","breadcrumb":{"@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/proctor-moulds-and-rammers\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.liyatest.com.tr\/en\/urun\/proctor-moulds-and-rammers\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/proctor-moulds-and-rammers\/#primaryimage","url":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/08\/LT_PROKTORKALIPTOKMAK.jpg","contentUrl":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/08\/LT_PROKTORKALIPTOKMAK.jpg","width":1200,"height":1200,"caption":"Proktor Kal\u0131p ve Tokmaklar ASTM ve EN zemin s\u0131k\u0131\u015ft\u0131rma ekipmanlar\u0131"},{"@type":"BreadcrumbList","@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/proctor-moulds-and-rammers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Anasayfa","item":"https:\/\/www.liyatest.com.tr\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.liyatest.com.tr\/en\/products\/"},{"@type":"ListItem","position":3,"name":"Proctor Moulds and Rammers"}]},{"@type":"WebSite","@id":"https:\/\/www.liyatest.com.tr\/en\/#website","url":"https:\/\/www.liyatest.com.tr\/en\/","name":"L\u0130YA TEST","description":"DISCOVER THE QUALITY","publisher":{"@id":"https:\/\/www.liyatest.com.tr\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.liyatest.com.tr\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.liyatest.com.tr\/en\/#organization","name":"L\u0130YA LABORATUVAR TEST C\u0130HAZLARI","url":"https:\/\/www.liyatest.com.tr\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.liyatest.com.tr\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/05\/logo-footer.png","contentUrl":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/05\/logo-footer.png","width":220,"height":113,"caption":"L\u0130YA LABORATUVAR TEST C\u0130HAZLARI"},"image":{"@id":"https:\/\/www.liyatest.com.tr\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/p\/LYA-LABORATUVAR-TEST-CHAZLARI-MALAT-PAZARLAMA-100069030777066\/","https:\/\/www.linkedin.com\/in\/liya-testing-equipment-9b7997106\/","https:\/\/www.instagram.com\/liya_test_equipment\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product\/13507","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/media\/11800"}],"wp:attachment":[{"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/media?parent=13507"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product_brand?post=13507"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product_cat?post=13507"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product_tag?post=13507"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}