{"id":13282,"date":"2026-07-28T12:00:42","date_gmt":"2026-07-28T09:00:42","guid":{"rendered":"https:\/\/localhost\/wordpress\/?post_type=product&#038;p=13282"},"modified":"2026-09-07T11:56:55","modified_gmt":"2026-09-07T08:56:55","slug":"cleveland-open-cup-flash-and-fire-point-tester","status":"publish","type":"product","link":"https:\/\/www.liyatest.com.tr\/en\/urun\/cleveland-open-cup-flash-and-fire-point-tester\/","title":{"rendered":"Cleveland Open Cup Flash and Fire Point Tester"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text css=&#8221;&#8221; woodmart_inline=&#8221;no&#8221; text_larger=&#8221;no&#8221;]<\/p>\n<h2 class=\"PDq2pG_selectionAnchorContainer\" data-start=\"2928\" data-end=\"2988\">What Is a Cleveland Open Cup Flash and Fire Point Tester?<\/h2>\n<p data-start=\"2990\" data-end=\"3294\">The <strong data-start=\"2994\" data-end=\"3044\">Cleveland Open Cup Flash and Fire Point Tester<\/strong> determines the flash and fire points of petroleum products under controlled laboratory conditions. The system follows the Cleveland open cup method and helps laboratories evaluate the thermal behaviour of suitable petroleum and bituminous materials.<\/p>\n<p data-start=\"3296\" data-end=\"3599\">The flash point indicates the temperature at which vapours above the sample can ignite momentarily when exposed to a test flame. The fire point represents the temperature at which combustion continues. Therefore, both values provide useful information for product characterisation and safety assessment.<\/p>\n<p data-start=\"3601\" data-end=\"3749\">ASTM D92 covers determination of flash and fire points using manual or automatic Cleveland open cup apparatus.<\/p>\n<h2 data-start=\"3751\" data-end=\"3784\">Cleveland Open Cup Test Method<\/h2>\n<p data-start=\"3786\" data-end=\"3949\">The operator pours the prepared sample into the <strong data-start=\"3834\" data-end=\"3852\">brass test cup<\/strong>. The heating system then gradually increases the sample temperature under controlled conditions.<\/p>\n<p data-start=\"3951\" data-end=\"4168\">During heating, the test flame is passed across the surface at specified intervals. The operator monitors the sample until the flash point is observed. Heating then continues when fire point determination is required.<\/p>\n<p data-start=\"4170\" data-end=\"4439\">ASTM D92 is intended for petroleum products tested using the Cleveland open cup method and defines flash point as an important indicator of the material&#8217;s tendency to form a flammable vapour-air mixture under controlled conditions.<\/p>\n<h2 data-start=\"4441\" data-end=\"4477\">Controlled Heating and Test Flame<\/h2>\n<p data-start=\"4479\" data-end=\"4647\">The integrated heater increases the sample temperature progressively. Controlled heating helps maintain consistent test conditions and supports repeatable measurements.<\/p>\n<p data-start=\"4649\" data-end=\"4859\">The ignition unit can operate with gas or liquefied petroleum gas. The test flame is applied according to the selected procedure, allowing the operator to observe the sample response at increasing temperatures.<\/p>\n<h2 data-start=\"4861\" data-end=\"4895\">Accurate Temperature Monitoring<\/h2>\n<p data-start=\"4897\" data-end=\"5079\">A dedicated thermometer continuously monitors the sample temperature during the test. This allows the operator to identify the temperature corresponding to the flash and fire events.<\/p>\n<p data-start=\"5081\" data-end=\"5214\">Clear temperature observation is important because the reported result directly depends on the temperature at the moment of ignition.<\/p>\n<h2 data-start=\"5216\" data-end=\"5244\">Compact Laboratory Design<\/h2>\n<p data-start=\"5246\" data-end=\"5428\">The <strong data-start=\"5250\" data-end=\"5263\">LT-AS0105<\/strong> has external dimensions of approximately <strong data-start=\"5305\" data-end=\"5324\">25 \u00d7 30 \u00d7 25 cm<\/strong> and weighs about <strong data-start=\"5342\" data-end=\"5351\">11 kg<\/strong>. Its compact structure allows convenient installation on a laboratory bench.<\/p>\n<p data-start=\"5430\" data-end=\"5632\">The unit operates with a <strong data-start=\"5455\" data-end=\"5488\">220 V, 50\u201360 Hz, single-phase<\/strong> electrical supply. The standard configuration also includes the thermometer and brass Cleveland test cup.<\/p>\n<h2 data-start=\"5634\" data-end=\"5660\">Laboratory Applications<\/h2>\n<p data-start=\"5662\" data-end=\"5845\">The Cleveland Open Cup Flash and Fire Point Tester is suitable for petroleum laboratories, bitumen testing facilities, universities, research centres and quality control laboratories.<\/p>\n<p data-start=\"5847\" data-end=\"5983\">It can be used to evaluate petroleum products where the selected standard and material specification require Cleveland open cup testing.<\/p>\n<h2 data-start=\"5985\" data-end=\"6030\">Testing According to EN 22592 and ASTM D92<\/h2>\n<p data-start=\"6032\" data-end=\"6250\">The <strong data-start=\"6036\" data-end=\"6096\">LT-AS0105 Cleveland Open Cup Flash and Fire Point Tester<\/strong> supports testing according to <strong data-start=\"6127\" data-end=\"6152\">EN 22592 and ASTM D92<\/strong>. Liya Test currently lists both standards for this product.<\/p>\n<p data-start=\"6252\" data-end=\"6393\">ASTM D92 specifically covers flash and fire point determination using the Cleveland open cup apparatus.<\/p>\n<p data-start=\"6395\" data-end=\"6646\">Overall, the system combines controlled heating, reliable flame application and compact laboratory construction. Therefore, laboratories can determine the flash and fire points of suitable petroleum products under controlled and repeatable conditions.<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p><strong><span dir=\"auto\" style=\"vertical-align: inherit;\">STANDART:\u00a0 \u00a0 \u00a0<\/span><\/strong><em><span dir=\"auto\" style=\"vertical-align: inherit;\">EN 22592, ASTM D92<\/span><\/em><\/p>\n<div class=\"woocommerce-product-details__short-description\">\n<div class=\"woocommerce-product-details__short-description\">\n<p><strong>LT-AS0105\u00a0 \u00a0 \u00a0 \u00a0<\/strong><em>Cleveland Open Cup Flash and Fire Point Tester<\/em><\/p>\n<\/div>\n<p><strong>LT-AS0105\/1\u00a0 \u00a0<\/strong><em>Thermometer<\/em><\/p>\n<p><strong>LT-AS0105\/2\u00a0 \u00a0<\/strong><em>Brass Test Cup<\/em><\/p>\n<\/div>\n","protected":false},"featured_media":11530,"template":"","meta":[],"product_brand":[],"product_cat":[140,142],"product_tag":[],"class_list":["post-13282","product","type-product","status-publish","has-post-thumbnail","product_cat-bitumen-asphalt","product_cat-bitumen-testing","first","instock","shipping-taxable","product-type-grouped"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Cleveland Flash and Fire Point Tester | ASTM D92 | Liya Test<\/title>\n<meta name=\"description\" content=\"Cleveland Flash and Fire Point Tester for petroleum products with controlled heating and test flame according to EN 22592 and ASTM D92.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.liyatest.com.tr\/en\/urun\/cleveland-open-cup-flash-and-fire-point-tester\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Cleveland Flash and Fire Point Tester | ASTM D92 | Liya Test\" \/>\n<meta property=\"og:description\" content=\"Cleveland Flash and Fire Point Tester for petroleum products with controlled heating and test flame according to EN 22592 and ASTM D92.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.liyatest.com.tr\/en\/urun\/cleveland-open-cup-flash-and-fire-point-tester\/\" \/>\n<meta property=\"og:site_name\" content=\"L\u0130YA TEST\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/p\/LYA-LABORATUVAR-TEST-CHAZLARI-MALAT-PAZARLAMA-100069030777066\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-07T08:56:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/localhost\/wordpress\/wp-content\/uploads\/2026\/07\/LT_YUMUSAMANOKTASI-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"1200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/cleveland-open-cup-flash-and-fire-point-tester\\\/\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/cleveland-open-cup-flash-and-fire-point-tester\\\/\",\"name\":\"Cleveland Flash and Fire Point Tester | ASTM D92 | Liya Test\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/cleveland-open-cup-flash-and-fire-point-tester\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/cleveland-open-cup-flash-and-fire-point-tester\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/LT_YUMUSAMANOKTASI-1.jpg\",\"datePublished\":\"2026-07-28T09:00:42+00:00\",\"dateModified\":\"2026-09-07T08:56:55+00:00\",\"description\":\"Cleveland Flash and Fire Point Tester for petroleum products with controlled heating and test flame according to EN 22592 and ASTM D92.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/cleveland-open-cup-flash-and-fire-point-tester\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/cleveland-open-cup-flash-and-fire-point-tester\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/cleveland-open-cup-flash-and-fire-point-tester\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/LT_YUMUSAMANOKTASI-1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/LT_YUMUSAMANOKTASI-1.jpg\",\"width\":1200,\"height\":1200,\"caption\":\"Parlama ve Yanma Noktas\u0131 Tayin Cihaz\u0131 Cleveland a\u00e7\u0131k kap testi\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/cleveland-open-cup-flash-and-fire-point-tester\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Anasayfa\",\"item\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Cleveland Open Cup Flash and Fire Point Tester\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/\",\"name\":\"L\u0130YA TEST\",\"description\":\"DISCOVER THE QUALITY\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#organization\"},\"alternateName\":\"L\u0130YA\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#organization\",\"name\":\"L\u0130YA LABORATUVAR TEST C\u0130HAZLARI\",\"alternateName\":\"L\u0130YA TEST\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/logo-footer.png\",\"contentUrl\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/logo-footer.png\",\"width\":220,\"height\":113,\"caption\":\"L\u0130YA LABORATUVAR TEST C\u0130HAZLARI\"},\"image\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/p\\\/LYA-LABORATUVAR-TEST-CHAZLARI-MALAT-PAZARLAMA-100069030777066\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/liya-testing-equipment-9b7997106\\\/\",\"https:\\\/\\\/www.instagram.com\\\/liya_test_equipment\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Cleveland Flash and Fire Point Tester | ASTM D92 | Liya Test","description":"Cleveland Flash and Fire Point Tester for petroleum products with controlled heating and test flame according to EN 22592 and ASTM D92.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.liyatest.com.tr\/en\/urun\/cleveland-open-cup-flash-and-fire-point-tester\/","og_locale":"en_US","og_type":"article","og_title":"Cleveland Flash and Fire Point Tester | ASTM D92 | Liya Test","og_description":"Cleveland Flash and Fire Point Tester for petroleum products with controlled heating and test flame according to EN 22592 and ASTM D92.","og_url":"https:\/\/www.liyatest.com.tr\/en\/urun\/cleveland-open-cup-flash-and-fire-point-tester\/","og_site_name":"L\u0130YA TEST","article_publisher":"https:\/\/www.facebook.com\/p\/LYA-LABORATUVAR-TEST-CHAZLARI-MALAT-PAZARLAMA-100069030777066\/","article_modified_time":"2026-09-07T08:56:55+00:00","og_image":[{"width":1200,"height":1200,"url":"https:\/\/localhost\/wordpress\/wp-content\/uploads\/2026\/07\/LT_YUMUSAMANOKTASI-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/cleveland-open-cup-flash-and-fire-point-tester\/","url":"https:\/\/www.liyatest.com.tr\/en\/urun\/cleveland-open-cup-flash-and-fire-point-tester\/","name":"Cleveland Flash and Fire Point Tester | ASTM D92 | Liya Test","isPartOf":{"@id":"https:\/\/www.liyatest.com.tr\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/cleveland-open-cup-flash-and-fire-point-tester\/#primaryimage"},"image":{"@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/cleveland-open-cup-flash-and-fire-point-tester\/#primaryimage"},"thumbnailUrl":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/07\/LT_YUMUSAMANOKTASI-1.jpg","datePublished":"2026-07-28T09:00:42+00:00","dateModified":"2026-09-07T08:56:55+00:00","description":"Cleveland Flash and Fire Point Tester for petroleum products with controlled heating and test flame according to EN 22592 and ASTM D92.","breadcrumb":{"@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/cleveland-open-cup-flash-and-fire-point-tester\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.liyatest.com.tr\/en\/urun\/cleveland-open-cup-flash-and-fire-point-tester\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/cleveland-open-cup-flash-and-fire-point-tester\/#primaryimage","url":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/07\/LT_YUMUSAMANOKTASI-1.jpg","contentUrl":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/07\/LT_YUMUSAMANOKTASI-1.jpg","width":1200,"height":1200,"caption":"Parlama ve Yanma Noktas\u0131 Tayin Cihaz\u0131 Cleveland a\u00e7\u0131k kap testi"},{"@type":"BreadcrumbList","@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/cleveland-open-cup-flash-and-fire-point-tester\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Anasayfa","item":"https:\/\/www.liyatest.com.tr\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.liyatest.com.tr\/en\/products\/"},{"@type":"ListItem","position":3,"name":"Cleveland Open Cup Flash and Fire Point Tester"}]},{"@type":"WebSite","@id":"https:\/\/www.liyatest.com.tr\/en\/#website","url":"https:\/\/www.liyatest.com.tr\/en\/","name":"L\u0130YA TEST","description":"DISCOVER THE QUALITY","publisher":{"@id":"https:\/\/www.liyatest.com.tr\/en\/#organization"},"alternateName":"L\u0130YA","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.liyatest.com.tr\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.liyatest.com.tr\/en\/#organization","name":"L\u0130YA LABORATUVAR TEST C\u0130HAZLARI","alternateName":"L\u0130YA TEST","url":"https:\/\/www.liyatest.com.tr\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.liyatest.com.tr\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/05\/logo-footer.png","contentUrl":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/05\/logo-footer.png","width":220,"height":113,"caption":"L\u0130YA LABORATUVAR TEST C\u0130HAZLARI"},"image":{"@id":"https:\/\/www.liyatest.com.tr\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/p\/LYA-LABORATUVAR-TEST-CHAZLARI-MALAT-PAZARLAMA-100069030777066\/","https:\/\/www.linkedin.com\/in\/liya-testing-equipment-9b7997106\/","https:\/\/www.instagram.com\/liya_test_equipment\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product\/13282","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/media\/11530"}],"wp:attachment":[{"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/media?parent=13282"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product_brand?post=13282"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product_cat?post=13282"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product_tag?post=13282"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}