{"id":13152,"date":"2026-07-23T12:46:15","date_gmt":"2026-07-23T09:46:15","guid":{"rendered":"https:\/\/localhost\/wordpress\/?post_type=product&#038;p=13152"},"modified":"2026-09-04T18:05:58","modified_gmt":"2026-09-04T15:05:58","slug":"blaine-permeability-apparatus","status":"publish","type":"product","link":"https:\/\/www.liyatest.com.tr\/en\/urun\/blaine-permeability-apparatus\/","title":{"rendered":"Blaine Permeability Apparatus"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text css=&#8221;&#8221; woodmart_inline=&#8221;no&#8221; text_larger=&#8221;no&#8221;]<\/p>\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-start=\"3677\" data-end=\"3736\">Blaine Permeability Apparatus for Cement Fineness Testing<\/h1>\n<p data-start=\"3738\" data-end=\"4007\">The <strong data-start=\"3742\" data-end=\"3775\">Blaine Permeability Apparatus<\/strong> determines the fineness of hydraulic cement by measuring its <strong data-start=\"3837\" data-end=\"3887\">specific surface area through air permeability<\/strong>. A prepared cement bed is compacted to a defined condition, and a controlled volume of air passes through the specimen.<\/p>\n<p data-start=\"4009\" data-end=\"4252\">The time required for the air to pass through the cement bed is measured and compared with calibration data from a reference material. This method is widely used for monitoring cement grinding consistency.<\/p>\n<h2 data-start=\"4254\" data-end=\"4287\">Manual U-Tube Manometer System<\/h2>\n<p data-start=\"4289\" data-end=\"4429\">The apparatus uses a <strong data-start=\"4310\" data-end=\"4336\">U-tube glass manometer<\/strong> mounted vertically on a rigid stand. The manometer contains a suitable low-viscosity liquid.<\/p>\n<p data-start=\"4431\" data-end=\"4606\">A rubber aspirator bulb raises the liquid to the required starting position. Once the pressure difference is created, air begins to flow through the compacted cement specimen.<\/p>\n<p data-start=\"4608\" data-end=\"4708\">The operator records the time required for the manometer liquid to move between the specified marks.<\/p>\n<h2 data-start=\"4710\" data-end=\"4746\">Stainless Steel Permeability Cell<\/h2>\n<p data-start=\"4748\" data-end=\"4937\">The test assembly includes a <strong data-start=\"4777\" data-end=\"4843\">stainless steel permeability cell, perforated disc and plunger<\/strong>. Filter paper is positioned above the perforated disc before the cement sample is introduced.<\/p>\n<p data-start=\"4939\" data-end=\"5242\">The plunger compacts the specimen to the required bed volume. Consistent specimen preparation is important because changes in bed porosity directly affect air-flow time. ASTM C204-26 specifies this type of manually operated apparatus as the reference Blaine method.<\/p>\n<h2 data-start=\"5244\" data-end=\"5282\">Calibration with Reference Material<\/h2>\n<p data-start=\"5284\" data-end=\"5402\">The Blaine method is comparative. Therefore, the apparatus must be calibrated using an appropriate reference material.<\/p>\n<p data-start=\"5404\" data-end=\"5542\">Liya Test supplies <strong data-start=\"5423\" data-end=\"5477\">LT-CE0005\/7 Calibration Sand in two 100 ml bottles<\/strong> as a separate accessory.<\/p>\n<p data-start=\"5544\" data-end=\"5637\">Calibration helps establish the apparatus constant used during specific-surface calculations.<\/p>\n<h2 data-start=\"5639\" data-end=\"5678\">What Does the Blaine Value Indicate?<\/h2>\n<p data-start=\"5680\" data-end=\"5807\">Blaine fineness represents the total surface area of cement per unit mass. Results are commonly reported as <strong data-start=\"5788\" data-end=\"5806\">cm\u00b2\/g or m\u00b2\/kg<\/strong>.<\/p>\n<p data-start=\"5809\" data-end=\"6081\">A higher Blaine value generally indicates a finer cement. However, the method does not directly determine individual particle sizes. EN 196-6 also notes that the method primarily supports consistency control of the grinding process.<\/p>\n<h2 data-start=\"6083\" data-end=\"6116\">EN 196-6 and ASTM C204 Testing<\/h2>\n<p data-start=\"6118\" data-end=\"6286\"><strong data-start=\"6118\" data-end=\"6135\">EN 196-6:2018<\/strong> includes the Blaine air-permeability method as one of the standard techniques for determining cement fineness.<\/p>\n<p data-start=\"6288\" data-end=\"6507\"><strong data-start=\"6288\" data-end=\"6304\">ASTM C204-26<\/strong> covers both manually operated and qualified automated Blaine apparatus. For this <strong data-start=\"6386\" data-end=\"6412\">LT-CE0005 manual model<\/strong>, the relevant reference approach is <strong data-start=\"6449\" data-end=\"6466\">Test Method A<\/strong>.<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p><strong><span dir=\"auto\" style=\"vertical-align: inherit;\">STANDART:\u00a0 \u00a0 <\/span><\/strong><em><span dir=\"auto\" style=\"vertical-align: inherit;\">TS EN 196-6; ASTM C204; AASHTO T153<\/span><\/em><\/p>\n<div class=\"woocommerce-product-details__short-description\">\n<div class=\"woocommerce-product-details__short-description\">\n<p><strong>LT-CE0005\u00a0 <\/strong>\u00a0 \u00a0 \u00a0 \u00a0 <em>Blaine Permeability Apparatus<\/em><\/p>\n<p><strong>LT-CE0005\/1\u00a0 <\/strong>\u00a0 \u00a0 <em>U Tube Manometer<\/em><\/p>\n<p><strong>LT-CE0005\/2 <\/strong>\u00a0 \u00a0 <em data-start=\"2451\" data-end=\"2490\">Cell with Perforated Disc and Plunger<\/em><\/p>\n<p><strong>LT-CE0005\/3\u00a0 <\/strong>\u00a0 \u00a0<em>Manometer Liquid\u00a0<\/em>|\u00a0<em>250ml<\/em><\/p>\n<p><strong>LT-CE0005\/4\u00a0 <\/strong>\u00a0 \u00a0 <em>Rubber Aspirator Bulb<\/em><\/p>\n<p><strong>LT-G0129\u00a0 <\/strong>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0<em>\u00a0 Plastic Funne<\/em>l<em>\u00a0<\/em>|\u00a0<em>100mm<\/em><\/p>\n<p><strong>LT-CE0005\/5\u00a0 <\/strong>\u00a0 \u00a0<em>Filter Paper <\/em>| <em>100 Pack<\/em><\/p>\n<p><strong>LT-CE0005\/6\u00a0 <\/strong>\u00a0 \u00a0<em>Filter Paper | 100 Pack<\/em><\/p>\n<p><strong>LT-CE0005\/7\u00a0 <\/strong>\u00a0 \u00a0<em>Calibration Sand<\/em><em>\u00a0\u00a0<\/em>| <em>100ml x 2 Bottles<\/em><\/p>\n<p><strong>LT-CE0005\/8\u00a0 \u00a0 \u00a0<\/strong><em data-start=\"2805\" data-end=\"2819\">Blaine Glass<\/em><\/p>\n<\/div>\n<\/div>\n","protected":false},"featured_media":11372,"template":"","meta":[],"product_brand":[],"product_cat":[167,168],"product_tag":[],"class_list":["post-13152","product","type-product","status-publish","has-post-thumbnail","product_cat-cement","product_cat-physical-chemical-testing-equipment","first","instock","shipping-taxable","product-type-grouped"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Blaine Permeability Apparatus | Cement Fineness Test | L\u0130YA Test<\/title>\n<meta name=\"description\" content=\"Blaine Permeability Apparatus measures cement fineness by air permeability using a U-tube manometer, stainless steel cell and aspirator.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.liyatest.com.tr\/en\/urun\/blaine-permeability-apparatus\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Blaine Permeability Apparatus | Cement Fineness Test | L\u0130YA Test\" \/>\n<meta property=\"og:description\" content=\"Blaine Permeability Apparatus measures cement fineness by air permeability using a U-tube manometer, stainless steel cell and aspirator.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.liyatest.com.tr\/en\/urun\/blaine-permeability-apparatus\/\" \/>\n<meta property=\"og:site_name\" content=\"L\u0130YA TEST\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/p\/LYA-LABORATUVAR-TEST-CHAZLARI-MALAT-PAZARLAMA-100069030777066\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-04T15:05:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/localhost\/wordpress\/wp-content\/uploads\/2026\/07\/LT_BLAINEHAVAGECIRGENLIK.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"1200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/blaine-permeability-apparatus\\\/\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/blaine-permeability-apparatus\\\/\",\"name\":\"Blaine Permeability Apparatus | Cement Fineness Test | L\u0130YA Test\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/blaine-permeability-apparatus\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/blaine-permeability-apparatus\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/LT_BLAINEHAVAGECIRGENLIK.jpg\",\"datePublished\":\"2026-07-23T09:46:15+00:00\",\"dateModified\":\"2026-09-04T15:05:58+00:00\",\"description\":\"Blaine Permeability Apparatus measures cement fineness by air permeability using a U-tube manometer, stainless steel cell and aspirator.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/blaine-permeability-apparatus\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/blaine-permeability-apparatus\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/blaine-permeability-apparatus\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/LT_BLAINEHAVAGECIRGENLIK.jpg\",\"contentUrl\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/LT_BLAINEHAVAGECIRGENLIK.jpg\",\"width\":1200,\"height\":1200,\"caption\":\"Blaine Hava Ge\u00e7irgenlik Cihaz\u0131 \u00e7imento incelik ve \u00f6zg\u00fcl y\u00fczey testi\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/urun\\\/blaine-permeability-apparatus\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Anasayfa\",\"item\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Blaine Permeability Apparatus\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/\",\"name\":\"L\u0130YA TEST\",\"description\":\"DISCOVER THE QUALITY\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#organization\"},\"alternateName\":\"L\u0130YA\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#organization\",\"name\":\"L\u0130YA LABORATUVAR TEST C\u0130HAZLARI\",\"alternateName\":\"L\u0130YA TEST\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/logo-footer.png\",\"contentUrl\":\"https:\\\/\\\/www.liyatest.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/logo-footer.png\",\"width\":220,\"height\":113,\"caption\":\"L\u0130YA LABORATUVAR TEST C\u0130HAZLARI\"},\"image\":{\"@id\":\"https:\\\/\\\/www.liyatest.com.tr\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/p\\\/LYA-LABORATUVAR-TEST-CHAZLARI-MALAT-PAZARLAMA-100069030777066\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/liya-testing-equipment-9b7997106\\\/\",\"https:\\\/\\\/www.instagram.com\\\/liya_test_equipment\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Blaine Permeability Apparatus | Cement Fineness Test | L\u0130YA Test","description":"Blaine Permeability Apparatus measures cement fineness by air permeability using a U-tube manometer, stainless steel cell and aspirator.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.liyatest.com.tr\/en\/urun\/blaine-permeability-apparatus\/","og_locale":"en_US","og_type":"article","og_title":"Blaine Permeability Apparatus | Cement Fineness Test | L\u0130YA Test","og_description":"Blaine Permeability Apparatus measures cement fineness by air permeability using a U-tube manometer, stainless steel cell and aspirator.","og_url":"https:\/\/www.liyatest.com.tr\/en\/urun\/blaine-permeability-apparatus\/","og_site_name":"L\u0130YA TEST","article_publisher":"https:\/\/www.facebook.com\/p\/LYA-LABORATUVAR-TEST-CHAZLARI-MALAT-PAZARLAMA-100069030777066\/","article_modified_time":"2026-09-04T15:05:58+00:00","og_image":[{"width":1200,"height":1200,"url":"https:\/\/localhost\/wordpress\/wp-content\/uploads\/2026\/07\/LT_BLAINEHAVAGECIRGENLIK.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/blaine-permeability-apparatus\/","url":"https:\/\/www.liyatest.com.tr\/en\/urun\/blaine-permeability-apparatus\/","name":"Blaine Permeability Apparatus | Cement Fineness Test | L\u0130YA Test","isPartOf":{"@id":"https:\/\/www.liyatest.com.tr\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/blaine-permeability-apparatus\/#primaryimage"},"image":{"@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/blaine-permeability-apparatus\/#primaryimage"},"thumbnailUrl":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/07\/LT_BLAINEHAVAGECIRGENLIK.jpg","datePublished":"2026-07-23T09:46:15+00:00","dateModified":"2026-09-04T15:05:58+00:00","description":"Blaine Permeability Apparatus measures cement fineness by air permeability using a U-tube manometer, stainless steel cell and aspirator.","breadcrumb":{"@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/blaine-permeability-apparatus\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.liyatest.com.tr\/en\/urun\/blaine-permeability-apparatus\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/blaine-permeability-apparatus\/#primaryimage","url":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/07\/LT_BLAINEHAVAGECIRGENLIK.jpg","contentUrl":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/07\/LT_BLAINEHAVAGECIRGENLIK.jpg","width":1200,"height":1200,"caption":"Blaine Hava Ge\u00e7irgenlik Cihaz\u0131 \u00e7imento incelik ve \u00f6zg\u00fcl y\u00fczey testi"},{"@type":"BreadcrumbList","@id":"https:\/\/www.liyatest.com.tr\/en\/urun\/blaine-permeability-apparatus\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Anasayfa","item":"https:\/\/www.liyatest.com.tr\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.liyatest.com.tr\/en\/products\/"},{"@type":"ListItem","position":3,"name":"Blaine Permeability Apparatus"}]},{"@type":"WebSite","@id":"https:\/\/www.liyatest.com.tr\/en\/#website","url":"https:\/\/www.liyatest.com.tr\/en\/","name":"L\u0130YA TEST","description":"DISCOVER THE QUALITY","publisher":{"@id":"https:\/\/www.liyatest.com.tr\/en\/#organization"},"alternateName":"L\u0130YA","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.liyatest.com.tr\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.liyatest.com.tr\/en\/#organization","name":"L\u0130YA LABORATUVAR TEST C\u0130HAZLARI","alternateName":"L\u0130YA TEST","url":"https:\/\/www.liyatest.com.tr\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.liyatest.com.tr\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/05\/logo-footer.png","contentUrl":"https:\/\/www.liyatest.com.tr\/wp-content\/uploads\/2026\/05\/logo-footer.png","width":220,"height":113,"caption":"L\u0130YA LABORATUVAR TEST C\u0130HAZLARI"},"image":{"@id":"https:\/\/www.liyatest.com.tr\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/p\/LYA-LABORATUVAR-TEST-CHAZLARI-MALAT-PAZARLAMA-100069030777066\/","https:\/\/www.linkedin.com\/in\/liya-testing-equipment-9b7997106\/","https:\/\/www.instagram.com\/liya_test_equipment\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product\/13152","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/media\/11372"}],"wp:attachment":[{"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/media?parent=13152"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product_brand?post=13152"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product_cat?post=13152"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.liyatest.com.tr\/en\/wp-json\/wp\/v2\/product_tag?post=13152"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}